ACTIVE STUDIO MONITORSOWNERSMANUAL
Preliminary RecommendationA word of warning on high sound levels - these speakers are capable of generating high output levels over sustainedperiods o
Master & Slave ConceptTwo types of hardware exist for each Precision 6 iDP™ and Precision 8 iDP™ (with the exception of the subwoofer –Slave only)
Slave Monitor & SubwooferThe slave unit is able to receive and distribute audio and control data via the proprietary TC LINK connectionThe TS112 i
Master Unit1. System controller/slave switch.In the “out” position the monitor operatesas a System Controller.* There can only be one system Controll
ENTERENTERENTEREXITENTERENTERENTERENTERENTERENTERENTER5h3h2.5h2.41.5h1hENTERENTERENTERDuration beforePowersaveENTERParameter structure accessible via
The iDP™ Display - MasterEXITENTERINTERACTIVE DIGITAL PROGRAMMINGENTER keyThe ENTER key has two main functions: To enter the menus currently displayed
SetupsGeneral Setup ProcedureDecide which Setup you are going to build.Connect the Precision iDP™ monitors exactly as shown on the following pages.Pow
Analog Stereo Set-up With Stereo SubsThe diagram shows how to connect a stereo set-up with two subwoofers.The Left monitor is set as the System Contro
5.1 Analog Set-upThe diagram shows how to connect a 5.1 analog set-up.The Centre monitor is set as the System Controller by leavingout the TC Link but
195.1 Digital 192kHz Set-upThe diagram shows how to connect a 5.1 digital set-up at 192khz.All Master monitors require installed digital I/O cards.AES
206.1 Digital Set-upThe diagram shows how to connect a 6.1 digital set-up.All Master monitors require installed digital I/O cards.AES signal is fed to
7.1 Analog Set-upThe diagram shows how to connect a 7.1 SDDS™ analog set-up.The Centre monitor is set as the System Controller by leavingout the TC Li
227.1 Digital 192kHz Set-upThe diagram shows how to connect a 7.1 SDDS™ 192kHz set-up.The Centre monitor is set as the System Controller by leaving ou
23Connecting Two SubsTwo Subs can be connected to any of the above Set-UpsWhen no Bass management is selected, no signal will be sent tothe subwoofers
245.1 Dig/6 - MasterThe diagram shows how to connect a 5.1 digital set-up using a singlemaster unit. The set-up requires one master monitor with the D
25SETUP when the monitors are connectedThe following is a simple operational setup guide, which is carried out after the monitors are connected. The a
6. Reset ProcedureThree different levels of “Reset” exist. For the three Reset levels all connected monitors will be affected.Select between the follo
27Parameter DescriptionBasic operation in all menus (when navigating the menus via the LCD display)Use ARROW keys to select value or submenuUse ENTER
Bass ManagementBass management (sometimes called bass redirection) is a very important and useful tool. With conventional studiomonitors external elec
29Setup Menu Press ENTER to access sub-menusSetup Press ENTER to access select mode. Select mode is indicated by “ * ” Press ENTER to confirm choiceEm
4 Important Safety Instructions5 Quick Set-Up Guide7 Introduction8 Concept & Design Philosophy9 Unpacking & Visual Checks10 Preliminary Recomm
30Parameters available for Precision 6 iDP™ and Precision 8 iDP™:-Pink Noise - On/OffCalibrate - Level calibration of the selected monitor. Range –6
31Parameter CategoriesGlobal ParametersThese parameters apply to the entire system: -Global parameters stored with presets• Bass Management• Mute St
32iDP™ RemoteThe iDP™ remote is available and can perform the following functions: -Instant access of three different user defined Reference Level set
33iDP™ Remote (cont.)Description of Functions:-REF LEVEL keys 1-3To recall Reference Levels 1-3:Press relevant key shortly. The key LED indicates acti
34iDP SOFT™iDP SOFT™ is a software editor for the Precision iDP™ monitors. All parameters that can be controlled using the displayon the System Contro
35iDP SOFT™ (cont.)This is the Main screen from where all other iDP SOFT™ screens are accessed.When The (((•))) network icon (upper left corner)Is ste
36iDP SOFT™ (cont.)Preset ListClicking on the left side of the display frame accesses the Preset List.Presets includePreset VolumeMute statusBass Mana
37iDP SOFT™ (cont.)NetworkAccessing the Network ScreenPress the ((( ))) icon in the Main screen to access the Network facilities. In this screen vario
38iDP SOFT™ (cont.)During Software upload various messages could be displayed:Example:“Precision monitor updated successfully” means the Precision mon
Monitor AssignmentTaskPress monitor symbol to activate pink noise test-tone.Then select task for the monitor now playing the noise. Serial number and
IMPORTANT SAFETY INSTRUCTIONSIMPORTANT SAFETY INSTRUCTIONS1 Read these instructions.2 Keep these instructions.3 Heed all warnings.4 Follow all ins
iDP SOFT™ (cont.)Calibrated LevelLevel calibration of the selected monitor.Relative LevelPreset volume for the selected monitor relative to the calibr
41iDP SOFT™ (cont.)PhaseRange: 0-180°To time-compensate if the Sub cannot be placed according to the ITU 775 recommendations. There are individual Pha
42Chained monitorsIf several monitors are chained on the same task (e.g. LSur-LSChain) a dropdown menu will appear as shown below. To calibrate achain
43Technical Specifications - Precision 6 iDPSystem (Master & Slaves)System 3-Way semi-active near field monitorFrequency Response (1) 56Hz – 51k
44Technical Specifications- Precision 8 iDPSystem (Master & Slaves)System 3-Way semi-active near field monitorFrequency Response (1) 43Hz – 51kHz
45Technical Specifications - TS212 iDP™ & TS112 iDP™ Subwoofer & iDP™ RemoteTechnical Specifications TS212 iDP™ SubwooferSystem Active Subwo
46Dimensions : Precision 6 iDP™Precision 6 iDP™ACTIVE STUDIO MONITORS220.0mm (85/8”)356mm (14”)369.0mm (141/2”)337.0mm (131/4”)
47Dimensions : Precision 8 iDP™Precision 8 iDP™272mm (103/4”)440mm(175/16”)369.0mm (141/2”)337.0mm (131/4”)
48Dimensions : Precision TS212 iDP™ (Grey/Silver)471mm (18 9/16”)498mm(19 5/8”)520mm (201/2”)Dimensions : Precision TS112 iDP™ (Grey)398mm (155/8”)384
49iDP™ Display MessagesThe following is an explanation of Error Messages, etc may appear on a Master monitor Display:-"!" as "96 kHz Ce
QUICK SETUP GUIDEBelow is a quick guide on how to connect different variations of setups. Connections must be made exactly as illustrated.Detailed des
50System DelaysSample Rate Digital Input Analog Input*AES or WC Converter Samples m/seconds cm Samples @ m/seconds cmin kHz kHz @ input Rate Converte
Preset # Display Name 1 thru 15 Empty or User Preset Presets 1 - 15 are "empty" until you choose to store a custom preset; after which it w
52CablesBelow is a guide to the cables used in iDP™ set-up’s.TC LINK Standard Cat-5 cablesMaximum Cable Length : 15 metres.Cable type : Shielded Ether
53Declaration Of ConformityThe following apparatus is/are manufactured in the United Kingdom by Tannoy Ltd of RosehallIndustrial Estate, Coatbridge, S
54WarrantyNo maintenance of the Precision iDP™ Monitor is necessary.All components are guaranteed for a period of one year from the date of manufactur
Check periodically for the latest manual revision that will always available for download fromwww.tannoy.com The issue number of this manual is locate
NOTE (7.1 only)If you wish to set up your system with side channels as opposed tofive “screen” channels:Simply substitute LI (Left Inner) & RI (Ri
IntroductionIn order to maintain our leading position in the worldwide professional studio market, the core technologies of Tannoyare constantly being
8Concept & Design PhilosophyThe following is an introduction to the concept behind the iDP™ system. Detailed setup guides and explanations of allo
TANNOY WideBand™ SuperTweeter™The Tannoy SuperTweeter™ extends the amplitude response beyond 20kHz audibility to 51kHz to correct the phaseresponse fr
Comentários a estes Manuais